INDICATOR CONTROLLER

UT-101

  • ON / OFF CONTROLLER (SINGLE DISPLAY)

     

    ♦ Microprocessor Based Powerful & Highly Reliable Controller.

    ♦ Universal Input T/C, RTD, Linear Input Selection.

    ♦ Potential Free Relay Contact Output Up To 1 / 2 / 3 / 4 Nos.

    ♦ 0.1% Accuracy Of FSD.

    ♦ Isolated 0/4-20 mA Process Value Re-Transmission Output.

    ♦ All Configurations And Calibrtion From Front Panel Keypad.

    ♦ Highly Communicative Serial Interface Facility (RS 232/485).

    ♦ Transmitter Loop Power Supply With Current Limit As Standard.

    ♦ Power Supply :230 V/110 V AC. Or 24 V/12 V DC.

    ♦ Optional GSM Mobile Connectivity.

    ♦ Fully Password Protected Operation.

    ♦ User Friendly Menu For Device Configurations & Calibration.

    ♦ Field Configurable.

    ♦ All Different Input In Single Controller.

  • FEATURE

     

    ♦ Microprocessor based powerful & highly reliable controller.

    ♦ Universal Input T/C, RTD, linear input selection.

    ♦ Potential Free Relay contact output up to 1 / 2 / 3 / 4 Nos.

    ♦ 0.1% Accuracy of FSD.

    ♦ Isolated 0/4-20 mA process value retransmission output.

    ♦ All Configurations and Calibration from front panel keypad.

    ♦ High speed communicative serial (RS 232/485) interface.

    ♦ Transmitter loop power supply with current limit as standard.

    ♦ Power supply : 230V/110V AC or 24V/12V DC.

    ♦ Optional GSM mobile connectivity.

    ♦ Fully Password Protected Operation.

INPUT Input Type T/C K, J, R, S, E, N, T
RTD Pt-100, Cu53 ( 2wire & 3 wire)
Current 0 - 20mA DC, 4 - 20mA DC
Voltage 0 - 5 V / 1 - 5 V / 0.5 -2.5V / 0 - 10 V DC
Special on demand 0-75/200 mV & 0-1/10V/100/300 V AC/DC
0-75/200 mV 0-100/300V DC
Resistance 0-500 R , 0-1/5/10 K, 1M
Transmitter Power Supply 24 V DC @ 30 mA max, isolated from I/P & O/P
Cold Junction Comp. & Sensor Break Ind. Software base Automatic
Range limits As per input range Table
Accuracy +/- 0.1 % of span for linear & RTD, +/-0.25 % for T/C
Input Impedance >330 K for Voltage ,mV, and T/C, 100 R for current
INDICATION Indication PV & SV for UT - 102 & PV for UT - 101 - LED 4 digit 7 segment display.
Status Indication LEDs for Relay Status & Communication
Alarm Modes Low / High
CONTROL MODE On / Off Control Relay / SSR
Dead Band Controls High & Low Set Point for Level Application
OUTPUT Relay Output NO - C - NC Contacts , 5A @240 V AC Resistive
SSR Output 1 / 2 / 3 / 4 Relays / SSR output
Transmitter Power 24 V DC @ 20 mA, 12 V DC @ 20 mA DC
Retransmission Current & Voltage Outputs 0 - 20 / 4 - 20 mA, 0 - 5 / 0 - 10 V / 1 - 5 V DC Isolated
COMMUNICATION Communication Protocol & Mathod Modbus RTU RS- 485/RS- 232 Communication
Programmable Parameter Baud Rate, Parity, Node Address, Stop Bit & 0-256 Unit
Wireless Communication GSM / GPRS base Mobile(SMS) Communication
PROGRAMMABLE PARAMETER Setpoint / Hysteresis / High Scale / Low Scale Full Range as per Input Selection.
Relay Logic F.S. High & Low Alarm, Dead Band Alarm
Display Resolution -1999 to 9999 Fully Configurable for Linear Input
Prameter Programming Through 4 Tactile Keys
OTHER Dimension & Mounting As per Box Selection Panel Mount/ Weather Proof / FLP Wall Mount
(A) Supply Voltage (B) Power Consumption (A) 110/230 V AC / 24 V DC, 50/60 Hz (B) 4 watts maximum
Operating Ambient Temperature and Humidity Temp. 0 - 50 °C , and Humidity: Below 90% Non Condensing