INDICATOR CONTROLLER

UT-201 T + T

  • Dual Channel Process Universal Indicator

     

    ♦ Micro-Controller Based Power, Full & Highly Reliable Controller.

    ♦ 2 Nos. Universal Input T/C, RTD, Linear Input Selection.

    ♦ Potential Free Relay Contact Output Up To 1/2/3/4 Nos.

    ♦ 0.1% Accuracy Of FSD.

    ♦ Isolated 2 X 0/4-20 mA Process Value Retransmission Output.

    ♦ All Configurations And Calibration From Front Panel Keypad.

    ♦ Highly Communicative Serial Interface Facility (RS 232/485).

    ♦ Transmitter Loop Power Supply With Current Limit As Standard.

    ♦ Power Supply :230V/110V AC. Or 24V/12V DC.

    ♦ Optional GSM Mobile Connectivity.

    ♦ Fully Password Protected Operation.

    ♦ Transmitter Loop Power Supply With Current Limit As Standard.

  •  FEATURE

     

    ♦ µP Based Power, full & highly reliable controller.

    ♦ 2 nos. Universal Input T/C, RTD, linear input selection.

    ♦ Potential Free Relay contact output up to 1/2/3/4

    ♦ 0.1% Accuracy of FSD.

    ♦ Isolated 2 X 0/4-20mA process value retransmission output.

    ♦ All Configurations and calibration from front panel keypad.

    ♦ Highly communicative serial interface facility (RS 232/485).

    ♦ Transmitter loop power supply with current limit as standard.

    ♦ Power supply :230V/110V AC. Or 24V/12V DC

    ♦ Optional GSM mobile connectivity.

    ♦ Fully Password Protected Operation.

INPUT INPUT Type For Channel-1 & Channel-2 T/C K, J, R, S, E, N, T
RTD Pt-100, Cu 53 ( 2 wire & 3 wire)
Current 0 ~ 20 mA DC, 4~20 mA DC
Voltage 0-5V/1-5V DC, 0.5 -2.5V/0- 10 V DC
Special on demand : 0-75/200 mV & 0-1/10V/100/300 V AC/DC
Resistance :- 0-75/200 mV 0-100/300V DC && 0-500 R , 0-1/5/10 K, 1M
Transmitter Power Supply 24 V DC @ 30 mA Max, Isolated From I/P & O/P
Cold Junction Comp. & Sensor Break Indication Software Base Automatic
Range Limits As Per Input Range Table
Accuracy +/- 0.1 % Of Span For Linear & RTD, +/-0.25 % For T/C
Input Impedance >330 K For Voltage ,mV DC, And T/C, 100 R For Current
INDICATION Indication PV & SV For UT102 & PV For UT101- LED 4 Digit 7 Segment Display.
Status Indication LEDs For Relay Status & Communication
Alarm Modes Very Low/Low/High/Very High
CONTROL MODE On Off Control Relay / SSR
Dead Band Controls High And Low Set Point For Level Application
OUTPUT Relay Output NO - C - NC Contacts , 5A@240 V AC Resistive
SSR Output 1 / 2 / 3 / 4 Relays / SSR Output
Transmitter Power 24 V DC @ 20 mA ,12 V DC @ 20 mA
Retransmission Current & Voltage Outputs 2 Nos. 0~20/ 4~20 mA DC , 0 ~ 5 V , 0 ~ 1 0 V DC , 1 ~ 5V DC, Fully 3 Port Isolated
COMMUNICATION Communication Protocol & Method Modbus RTU RS- 485/RS- 232 Communication
Programmable Parameter & Max No Baud Rate, Parity , Node Address , Stop Bit & 0-256 Unit
Wireless Communication GSM/GPRS Base Mobile(SMS) Communication
PROGRAMMABLE PARAMETER Set point / Hysteresis / High scale / Low Scale Full Range As Per Input Selection
Relay Logic F.S. High & Low Alarm, Dead Band Alarm
Display Resolution -1999 to 9999 Fully Configurable For Linear Input
Programming Of Parameters Through 4 Tactile Keys
OTHER Dimensions & Mounting As Per Box Selection & Wall/Structure 2/2 Holes
(A) Supply Voltage (B) Power Consumption (A) 110/230 V AC/24 V DC, 50/60 Hz (B) 4 Watts Maximum
Operating Ambient Temperature And Humidity 0~50 °C , And Humidity : Below 90%, Non Condensing