BATCH / FLOW CONTROLLER
♦ Potential Free Relay Contact Output 2 X Flow And 2 X Totalizer.
♦ Field Configurable Flow Range. Sort Key Function For Batch Start, Stop And Pause.
♦ Micro Controller Based Powerful & Highly Reliable Controller
♦ 8/10 Digit Flow Totalizer With Password Protected Reseƫng.
♦ Various Enclosures Supported Weather Proof Or Flame Proof.
♦ User Friendly Menu For Device Configurations & Calibration.
♦ Optional GSM Mobile Connectivity For Remote Data Reading And Logging Through SMS.
♦ Maximum 4 C/O On Batch Values Generated.
♦ 24 V DC Loop Power Supply For Flow Transmitter.
♦ 4-20 mA Or 0-10 V DC Or Pulse (3 & 2 Wire) Input Type.
♦ All Standard Batch Functions Included.
♦ Liner Or Square Root Input Selections & 0.1% Accuracy.
♦ Isolated 0/4-20 mA Re-Transmission Output.
♦ Flow And Batch Managements Computer SoŌware Available.
♦ Maximum 4 C/O on Batch values generated.
♦ Micro controller Based Powerful & highly reliable controller.
♦ 4-20 mA or 0-10 v or pulse (3 & 2 wire) input type.
♦ Potential Free Relay contact output 2 x flow and 2 x Totaliser.
♦ Liner or square root input selections with 0.1% Accuracy.
♦ Isolated 0/4-20mA retransmission output.
♦ All standard Batch Functions included.
♦ Highly communicative serial interface facility (RS 232/485).
♦ 24 v loop power supply for flow Transmitter
♦ 8/10 digit Flow Totaliser with password protected resetting.
♦ Various Enclosures supported Weather proof or flame proof.
♦ User friendly menu for device configurations & calibration.
♦ Field Configurable flow range. sort key function for batch Start, Stop and Pause.
♦ Flow and Batch computer software available.
♦ Optional GSM mobile connectivity for remote data reading and logging Through SMS.
INPUT | Input Type | Currant : | 0 ~ 20mA DC , 4~20mA DC |
Voltage: | 0-5V/1-5V, 0.5 -2.5V/0- 10V DC | ||
Pulse : | 3 wire PNP, NPN & 2 wire NAMUR type | ||
Transmitter power supply | 24 V DC @ 30 mA max, isolated from I/P & O/P | ||
Input mode | Linear or Square root | ||
Range limits | As per input range Table | ||
Accuracy | +/- 0.1 % of span for linear & RTD, +/-0.25 % for T/C | ||
Input impedance | >330 K for Voltage ,mV, and T/C, 100 R for current | ||
INDICATION | Indication | TOUCH LCD TYPE : | 3.5 inch touch screen 5 digit Flow rate & 10 digit Totaliser. |
LCD TYPE : | 5 digit Flow rate & 10 digit Totaliser-16x2 line back lite | ||
Status indication | LEDs for Relay status & Communication, start stop and push | ||
Alarm modes | Very Low / Low / High / very High | ||
CONTROL MODE | On Off control | Relay / SSR- With BATCH START, STOP & POSH FUNCTION | |
Batch Values & batch function | 2 (can be set in value or %) & Batch start, Stop and Posh function. | ||
OUTPUT | Relay Output | NO - C - NC Contacts , 5A@240 V AC Resistive | |
2 Relay output for Fine and corse output | |||
Transmitter Power | 24VDC @ 20 mA ,12VDC @ 20 mA | ||
Retransmission Current & Voltage outputs | 0~20/ 4~20 mA, 0 ~ 5 V , 0 ~ 1 0 V , 1 ~ 5V DC, fully 3 port isolated | ||
COMMUNICATION | Communication Protocol & mathod | Modbus RTU RS- 485/RS- 232 or Ethernet Communication | |
Programmable parameter & Max No. | Baud rate,Parity , Node address , Stop bit & 0-256 unit | ||
Wireless Communication | GSM/GPRS base mobile(sms) Communication | ||
PROGRAMMBALE
PARAMETERS |
Setpoint / Hysteresis / High scale / Low scale | Full range as per input selection. | |
Relay Logic | F.S. high & low alarm, Dead band alarm | ||
Display resolution | -1999 to 9999 fully configurable for linear input | ||
Programming of parameters | Through 4 tactile keys | ||
OTHER | Dimensions & Mounting | As per box selection & wall/structure 2/2 holes | |
(A) Supply voltage (B) Power consumption | (A) 110/230 AC/24VDC, 50/60 Hz (B) 4 watts maximum | ||
Operating ambient Temperature and Humidity | 0~50 °C , and humidity : Below 90%, non condensing |