REMOTE IOs MODULE (ANALOG/DIGITAL)
♦ Dual RS-485 Remote I/O With Built-In Repeater.
♦ 16 Bit High Accuracy Analog Input. Up To 60,000 Count.
♦ 2 Port MODBUS RTU Mul Drop RS-485 / Ethernet TCP-IP / RF Wireless / Wi-Fi / Bluetooth Comport Available
♦ Supports Of Mul-Drop Communications Parameters With Software Application For User Friendly Configuration
♦ LCD Display For Live PV And High And Low Alarming.
♦ Internal Data Memory With Time Stamping With Auto Data Backfilling Facility To Avoiding Data Loss.
♦ User Selectable Set Limits For Process Value Violaon & Inbuilt Audible Buzzer With Relay Output.
♦ Wide Operang Temperature Models Available For -40 To 85°C (-40 To 185°F) Environments.
♦ Compact DIN Rail Enclosure.
♦ High-Speed & Supports Up To 15 Clients On TCP/IP With Friendly Configuraon Via Web Browser.
♦ LED For Fault, Communicaon & Power. (12-24 V DC Power).
♦ Accepts T/C and 2- or 3-wire RTD sensors
♦ 2 wire technology 4 to 20 mA analogue output.
♦ Field programmable with easy to use MS Windows 7-based configuration software and a PC
♦ Consistent sensor break function
♦ Customer specific measurement range setting.
♦ Full access to all features while in operation
♦ An internal temperature sensor for active temperature compensation.
♦ Easy wiring with a large center holl.
♦ Zero span local adjustments.
♦ Simple & user friendly software Thought USB Communication
♦ Hade mounted and din rail model available.
| SPECIFICATION | Analog- UT-AI8, UAI4, AO4 | Digital- UT-12DI, 12DO, 12DIO |
| INPUT | 16 bit : 4 or 8 Nos. 0 / 4 - 20 mA DC, 0 - 2 / 5 / 10 V DC | DO or Pulse Output DI- On: Short to GND , Off: Open |
| OUTPUT | 4 or 8 Nos. 0 / 4 - 20 mA DC, 0 - 2 / 5 / 10 V DC | DO or Pulse Output DI- On: Short to GND , Off: Open |
| ACCURACY | 0.1 % of FS | NA |
| RESPONSE TIME | 50 m/s Per channel | 50 m/s Per channel |
| ETHERNET COMMUNICATION | > Modbus TCP/IP(Modbus / telnet ) | |
| RS485 COMMUNICATION | Modbus-RTU Slave x 2 nos | |
| WIRELESS WI-FI COMMUNICATION | Lora 2 KM Range. | |
| Wireless Wi-Fi Communication | Modbus TCP/IP(Modbus / telnet ). | |
| Power | 8 to 35 V AC/ DC | |
| Programming | IO- link software for Configuration & Diagnostics | |
| Dimension & Housing | 72 (W) x 130 (H) x 30 (D), ABS | |
| Status Indication | 3 mm LED OR 1.3 inch Graphical LCD | |
| Installation & Wiring | Din rail channel Mounted or wall mounted. | |
| Memory | 1 Lakh Data- Logging Time selectable : 1 to 5000 Seconds from software | |
| Connector | Screw-fastened Euro block terminal | |