LARGE TEMP+RH+TIME DISPLAY
♦ Large display size 2”/4”/6”/8”/12”/16” available.
♦ Large display size for easy viewing from a distance.
♦ Hanging /Rack/wall/panel mounting options with IP protection.
♦ Micro controller based indicator with inbuilt Temp.+ RH +Time measurement in single enclosure.
♦ All channel are programmable ranges and unit (Through Front key pad).
♦ Incorporates highly stable built-in Temp.+ RH sensor.
♦ Different size of display for displaying RH & Temperature and 4 digit for time.
♦ Process parameter High and Low LEDs status indication for all three channels.
♦ MODBUS RTU multi drop RS-485 serial communication for PLC, SCADA etc.
♦ Password protection for calibration and programming mode.
♦ Software Calibration for 3 channels.
♦ Programmable Device address, Baud rate, Parity and Stop bit.
♦ Local programing facility for real time with battery backup.
♦ User programmable offset correction.
♦ Brick/Wall mounting and panel mounting enclosure with IP protection.
♦ Optional GSM mobile connectivity.
♦ Large display size 2”/4”/6”/8”/12”/16” available.
♦ Large display size for easy viewing from a distance.
♦ Hanging /Rack/wall/panel mounting options with IP protection.
♦ Micro controller based indicator with inbuilt Temp.+ RH +Time measurement in single enclosure.
♦ All channel are programmable ranges and unit (Through Front key pad).
♦ Incorporates highly stable built-in Temp.+ RH sensor.
♦ Different size of display for displaying RH & Temperature and 4 digit for time.
♦ Process parameter High and Low LEDs status indication for all three channels.
♦ MODBUS RTU multi drop RS-485 serial communication for PLC, SCADA etc.
♦ Password protection for calibration and programming mode.
♦ Software Calibration for 3 channels.
♦ Programmable Device address, Baud rate, Parity and Stop bit.
♦ Local programing facility for real time with battery backup.
♦ User programmable offset correction.
♦ Brick/Wall mounting and panel mounting enclosure with IP protection.
♦ Optional GSM mobile connectivity.
| INPUT | Nos. Of Input | 1-(Temp + Rh) , 2-(Temp.+Rh+Real Time) |
| Temperature Input | Integral Or Remote (External:4-20 mA DC Or 0-10 V DC /RTD PT-100) | |
| Humidity Input | Integral Or Remote (External:4-20 MA Or 0-10 V DC) | |
| Transmitter Power Supply | 24V/5 V DC @ 30 mA Max, Isolated From I/P & O/P | |
| INDICATION | Temperature | Channel-1 : 3 Digit Seven Segments 1”/2”/4”/6”/12”” Display. |
| Humidity | Channel-2 : 3 Digit Seven Segments 1”/2”/4”/6”/12”/16” Display. | |
| Time | Channel-3 : 4 Digit Seven Segments 1”/2”/4”/6”/12”/16” Display. | |
| RANGE | Temperature | 0 To 60.0 *C With Decimal Point. |
| Humidity | 0 To 99.9 % With Decimal Point. | |
| Time | Hour : Minute 12 Or 24 Hour Formats 00:00 | |
| Display Resolution | 0.1 For Temp. & Rh | |
| ACCURACY | Temperature | 0.25 % On FS Response Time : 8 Sec |
| Humidity | 2.5 % For 10 To 90 % RH Rest Of 3% Response Time : 4 Sec | |
| Time | 0.01 % Response Time : 1 Sec | |
| COMMUNICATION | Communication Protocol | Modbus RTU RS- 485 Isolated Communication. |
| Programmable Parameter | Baud Rate , Parity , Node Address , Stop Bit.(Minute And Hour) | |
| No. Of Slave ID | Read: Process Value ,Decimal Point Write: High Low Set Point | |
| Read /Write Parameter | Total 1-256 Unit | |
| PROGRAMMBALE PARAMETER | Set Point / High Scale / Low Scale/Time(MM+HH) | Full Range As Per Input Selection |
| Programming Of Parameters | Through 4 Tactile Keys (With Password Protection) | |
| Alarm Logic | Full Scale High Or Full Scale Low | |
| OTHER | Mounting | Bricks And Modules Wall Flush Panel Mounting |
| Enclosure MOC | M S Powder Coated Enclosure | |
| Supply Voltage & Power Consumption | 230 V DC & As Per On Display Size | |
| Operating Ambient Temperature And Humidity | Temp: 0~60 °C Humidity: Below 90%, Non Condensing |