LARGE TEMP+RH+TIME DISPLAY
♦ Large Display Size 2”/4”/6”/8”/12”/16” Available.
♦ Large Display Size For Easy Viewing From a Distance.
♦ Hanging /Rack/Wall/Panel Mounting Options With IP Protection.
♦ IP-55 And IP-65 Housing Available.
♦ Microprocessor Based Power, Full & Highly Reliable Controller.
♦ Universal Input T/C, RTD, Linear Input Selecon.
♦ 0.1% Accuracy Of FSD.
♦ Potential Free Relay Contact Output Up To 1 / 2 / 3 / 4.
♦ All Configurations And Calibration From Front Panel Keypad.
♦ Highly Communicative Serial Interface Facility (RS-232/485).
♦ Power Supply :230 V/110 V AC Or 24 V/12 V DC.
♦ Optional GSM Mobile Connectivity.
♦ Fully Password Protected Operation.
♦ Large display size 2”/4”/6”/8”/12”/16” available.
♦ Large display size for easy viewing from a distance.
♦ Hanging /Rack/wall/panel mounting options with IP protection.
♦ Micro controller based indicator with inbuilt Temp.+ RH +Time measurement in single enclosure.
♦ All channel are programmable ranges and unit (Through Front key pad).
♦ Incorporates highly stable built-in Temp.+ RH sensor.
♦ Different size of display for displaying RH & Temperature and 4 digit for time.
♦ Process parameter High and Low LEDs status indication for all three channels.
♦ MODBUS RTU multi drop RS-485 serial communication for PLC, SCADA etc.
♦ Password protection for calibration and programming mode.
♦ Software Calibration for 3 channels.
♦ Programmable Device address, Baud rate, Parity and Stop bit.
♦ Local programing facility for real time with battery backup.
♦ User programmable offset correction.
♦ Brick/Wall mounting and panel mounting enclosure with IP protection.
♦ Optional GSM mobile connectivity.
INPUT | Input Type | T/C | K, J, R, S, E, N, T |
RTD | Pt-100, Cu53 ( 2Wire & 3 Wire) | ||
Current | 0 - 20 mA DC, 4 - 20 mA DC | ||
Voltage | 0 - 5 V / 1 - 5 V / 0.5 -2.5V / 0 - 10 V DC | ||
Special on demand | 0-75/200 mV & 0-1/10V/100/300 V AC/DC | ||
Resistance | 0-500 R , 0-1/5/10 K, 1M or 0-75/200 mV 0-100/300 V DC | ||
Transmitter Power Supply | 24 V DC @ 30 mA Max, Isolated From I/P & O/P | ||
Cold Junction Comp. & Sensor Break Ind. | Software Base Automatic | ||
Range Limits | As Per Input range Table | ||
Accuracy | +/- 0.1 % Of Span For Linear & RTD, +/-0.25 % For T/C | ||
Input Impedance | >330 K For Voltage ,mV, And T/C, 100 R For Current | ||
INDICATION | Indication | PV & SV For UT 102 & PV For UT101- LED 4 Digit 7 Segment Display | |
Status Indication | LEDs For Relay Status & Communication | ||
Alarm Modes | Very Low/Low/High/very High | ||
CONTROL MODE | On / Off Control | Relay / SSR | |
Dead Band Controls | High and Low Set Point For Level Application | ||
OUTPUT | Relay Output | NO - C - NC Contacts , 5 A @ 240 V AC Resistive | |
SSR Output | 1 / 2 / 3 / 4 Relays / SSR Output | ||
Transmitter Power | 24 V DC @ 20 mA, 12 V DC @ 20 mA | ||
Re-Transmission Current & Voltage Output | 0~20/ 4~20 mA, 0 ~ 5 V , 0 ~ 1 0 V , 1 ~ 5V DC, Fully 3 Port Isolated | ||
COMMUNICATION | Communication Protocol & Method | Modbus RTU RS- 485/RS- 232 Communication | |
Programmable Parameter & Max No. | Baud Rate, Parity, Node Address, Stop Bit & 0-256 Unit | ||
Wireless Communication | GSM / GPRS base Mobile(SMS) Communication | ||
PROGRAMMABLE PARAMETER |
Set Point / Hysteresis / High Scale / Low Scale | Full Range As Per Input Selection. | |
Relay Logic | F.S. High & Low Alarm, Dead Band Alarm | ||
Display Resolution | -1999 to 9999 Fully Configurable For Linear Input | ||
Parameter Programming | Through 4 Tactile Keys | ||
OTHER | Dimension & Mounting | As Per Box Selection & Wall/Structure 2/2 Holes | |
(A) Supply Voltage (B) Power Consumption | (A) 110/230 V AC / 24 V DC, 50/60 Hz (B) 4 Watts Maximum | ||
Operating Ambient Temperature And Humidity | Temp. 0 - 50 °C , And Humidity: Below 90% Non Condensing |