DOOR INTERLOCKING SYATEM
♦ Door Interlock For The Clean Rooms And Other Production Facilities For Good Manufacturing Practices.
♦ Single Controller Can Control 2,4 & 8 Door Systems And Its Go Maximum Up To 16 Doors With Cascade Feature
♦ Dedicated Ports For Emergency Switches & Door Position Sensor
♦ Available In Soft Touch Keyboard, Contact Less Ir Reader, Biometric Thumb Reader Or With Access Card Reader As Per App. Demands.
♦ Access Control Measures To Restrict Movements Of Personnel Across Production Facility To Prevent Contamination Us Fda Guidelines.
♦ Biometric Logical Access For Critical Pharma Machinery Integration Possible.
♦ 21 CFR Part 11 Compliant Software.
♦ Special Product For Data Centre And Server Room.
♦ Audio & Visual Indications & Flameproof Options Available
♦ Access Control At Any Other Vital Points Where It May Be Necessary To Restrict Or Regulate Entry.
♦ Enterprise Level In-house Developed Cloud Based Software With A Number Of Useful Reports And Analysis For The Management.
♦ The Master/Slave clocks finds application in processes where time synchronization is required.
♦ The MASTER clock can be connected to computer on RS232 port which is a serial data transmission.
♦ The SLAVE clocks are connected to the master on RS485 port which is a parallel data transmission.
♦ The range available is HOURS: MINUTES: SECONDS or HOURS: MINUTES. The clocks are available in 99 HRS: 99 MINUTES: 99 SECONDS.
♦ The state of art Micro controller assures time accuracy of 0.01 %.
♦ The clocks in the network displays the same time simultaneously.
♦ The maximum slave clocks possible on the network are 120.
♦ The Time and calendar configuration can be easily adjusted as per the user requirements.
♦ The user friendly GUI works on Windows XP/2000 platform.
♦ Master Slave time selection is optional either manual or by PC.
♦ Display height available is 8”/1”/2 “/4 “with red color and time tick LED indication.
♦ The instrument is designed with two/four relay outputs for process control or ALARMS.
♦ The power supply given to the device is 230 V/50 Hz AC.
♦ Micro Processor Based Master clock.
♦ Reliable 7-Segment LED display.
♦ Synchronizes all Slaves Every Second.
♦ Specially Designed for Clean Room Environment.
♦ Flicker-free Bright Red 7-Segment LED Display
♦ User friendly programming Modes.
♦ The instrument has EMI / RFI filters for harsh electrical environment.
♦ Time Displays in 12/24 Hrs Format (HH:MM:SS)
♦ Red filter Transparent overlay facilitates wide viewing angle
♦ Drives up to 120 Slave Clocks.
♦ Interface communication: RS-485
OUTPUT | |
Up to 16 Potential Free Output | |
Relay Contact Rating : 1.0 Amp for 12 V DC | |
Door EM LOCK Contact X 8 nos. | |
DOLT Buzzer Contact X 8 nos. | |
INPUT | |
Total 18 Optically Isolated Inputs | |
EM lock Contact 8 Nos. | |
Door Position Switch Contacts 8 Nos. | |
Emergency/Fire Contacts 2 Nos. | |
COMMUNICATION OUT | |
Quantity of Communication Port: 2 RS-485, 1 Ethernet Port & Wi-Fi | |
RS-485 Signal: D+, D-, GND. | |
Salve ID: User Programmable (1-255) | |
COMMUNICATION INPUT | |
Slave Up to 50 nos. Reader | |
RS-485 Signal: D+, D-, GND | |
RF Card Reader Or Biometrics Reader | |
MEMORY | Up to 8 MB (Flash) |
CONFIGURATION | |
WEB Configuration from RJ45 Ethernet Port | |
Windows Configuration Tool | |
PROGRAMMABLE PARAMETERS | |
Door Open Time Settings & Lock Time Setting, Valid Open Time Setting | |
Buzzer Sound Type & Time | |
Door Interlock Grouping | |
INDICATION | Power Supply Indicator, Ethernet port Indicator, RS-485 Port Indicator |
POWER SUPPLY | 230 V AC Supply |
PHYSICAL CHARACTERISTICS | |
Housing: MS Powder Coated | |
Installation: wall Mounted Or Panel Mounted. | |
Dimension (250-W x 250-H x 50-D): | |
STORAGE TEMP | Max 40 °C to 85 °C |
OPRATIGE TEMP. | Max 40 °C to 85 °C |