CLEAN ROOM / PHARMA INDICATORS

UT-1401-3

  • DP INDICATOR WITH SENSOR_3” LCD

     

    ♦ USFDA- 21 CFR Part 11 - GAMP-4 Compatible With Data Logging EMS SCADA Software.

    ♦ Compact, All Stainless Steel Enclosure With 35 mm Depth For Installation In Prefab Panels.

    ♦ MODBUS RTU Multi Drop RS-485 / Ethernet TCP-IP / RF Wireless / Wi-Fi / Blue Tooth Comport Available.

    ♦ Incorporates Highly Stable Digital Built-In Or Remote Sensor For Diff. Pressure.

    ♦ Red LED (0.56" Or 1") And Touch Screen LCD Display (3.2"/ 4"/ 7") For Displaying DP Or With Time.

    ♦ Internal Data Memory With Time Stamping With Auto Data Backfilling Facility To Avoiding Data Loss.

    ♦ User Selectable Set Limits For Process Value Violation & Inbuilt Audible Buzzer With Acknowledgments.

    ♦ Process Parameter Hi And Low LED Status Indication For All Three Channel With AHU On/Trip Status Indication.

    ♦ All Channel Ranges & Unit Are Programmable.(Through Front Key Pad & Touch Screen).

    ♦ 3 Level Password Protection For Calibration And Programming Mode.

    ♦ Time Display With Auto Masters, Sever (NTP) Or GPS Time Synchronised (HH : MM ).

    ♦ User Programmable Delay Time Selectable For Alarm (Alert Or Action).

    ♦ Brick And Modular Wall Mounting And Flush Mounting And Flameproof Model Available.

  •  FEATURE

     

    ♦ USFDA- 21 CFR Part 11 - GAMP-4 Compatible With Data Logging EMS SCADA SoŌware.

    ♦ Compact, All Stainless Steel Enclosure With 35 mm Depth For Installation In Prefab Panels.

    ♦ MODBUS RTU Multi Drop RS-485 / Ethernet TCP-IP / RF Wireless / Wi-Fi / Blue Tooth Comport Available.

    ♦ Incorporates Highly Stable Digital Built-In Or Remote Sensor For Diff. Pressure.

    ♦ Red LED (0.56" Or 1") And Touch Screen LCD Display (3.2"/ 4"/ 7") For Displaying DP Or With Time.

    ♦ Internal Data Memory With Time Stamping With Auto Data Backfilling Facility To Avoiding Data Loss.

    ♦ User Selectable Set Limits For Process Value Violation & Inbuilt Audible Buzzer With Acknowledgments.

    ♦ Process Parameter Hi And Low LED Status Indication For All Three Channel With AHU On/Trip Status Indication.

    ♦ All Channel Ranges & Unit Are Programmable.(Through Front Key Pad & Touch Screen)..

    ♦ 3 Level Password Protection For Calibration And Programming Mode.

    ♦ Time Display With Auto Masters, Sever (NTP) Or GPS Time Synchronised (HH : MM ).

    ♦ User Programmable Delay Time Selectable For Alarm (Alert Or Action)..

    ♦ Brick And Modular Wall Mounting And Flush Mounting And Flameproof Model Available.

INPUT Room Deff. Pressure. Integral Or Remote (4-20 mA & RS 485)
Nos. Of Input 1 Nos . (Dif. Pressure Or With Time)
Transmitter Power Supply 24 V/5V Dc @ 30 mA Max, Isolated From I/P & O/P.
INDICATION Diff. Room Pressure With Optional Time & Date Led : Red Seven Segment 0.56"/1", 6-Leds For Visual Alarms & Com.
LCD : 3.2 Inch / 4 Inch / 7 Inch- Touch Screen Multi Colour
RANGE Room Diff.Pressure. -150 To 150 Pa & -400 To 400 Pa, On Site mmWC Or Pascal Selectable.
-1000 To 1000 Pa & -10000 To 10000 Pa, On Site mmWC Or Pascal Select
Time Synchronized Date & Time Synchronised Trough Sever Or GPS With Built In RTC)
Display Resolution DP - mmWC - 0.1 & Pa - 1.
ACCURACY Room Diff. Pressure. 1 % On Fs Response Time : 1 Sec
Time Synchronized 0.01 % Response Time : 1 Sec
COMMUNICATION Communication Protocol Modbus RTC RS-485 & Ethernet Isolated, Wireless Rf, Wi-Fi, Bluetooth
Programmable Parameters. Baud Rate , Parity , Node Address , Stop Bit & Ip Address
Read /Write Parameters. Read: Process Value ,Decimal Point. Write: Hi Low Set Point.
No. Of Slave Id Total 1-128 Unit. With Programmable Ip Address.
PROGRAMMABLE PARAMETER Set Point / High Scale / Low Scale Full Range As Per Input Selection.
Programming Of Parameters Through 4 Tactile Keys & Touch Screen (With Password Protections)
Status Indication Full Scale High Or Full Scale Low.
MEMORY 1 Lakh Data With Auto Data Back Filling - Logging Time Selectable : 1 To 5000 Seconds From Software.
OTHER Mounting Bricks And Modules Wall Flush Panel Mounting.
Moc Full S S 316 Plate And Box , Back Side Wall Mounting Back Box M S
Supply Voltage & Power Consumption 24 V DC @ 4 Watts Maximum.
Ambient Temperature & Humidity Temp.:- 0- 50 °C Humidity Below 90% None Condensing.