FLOW RATE INDICATOR & TOTALIZER
♦ Accepts Universal Inputs: 4 – 20 mA Or 0 – 10 V DC Or Pulse (3 & 2 Wire) Input Type.
♦ Non-Volatile Memory To Retain Totalizer Flow, No Need To BaƩery Change.
♦ Potential Free Relay Contact Output 2 X Flow And 2 X Totalizer.
♦ Liner Or Square Root Input Selections With 0.1% Accuracy.
♦ Isolated 0 / 4 – 20 mA DC Retransmission Output Proportional To Standard Flow Rate.
♦ Field operated user friendly menu for device configurations & calibration.
♦ 8/10 digit Flow Totaliser with password protected reset.
♦ Fully password protection for tamper free operation.
♦ Isolated High speed communicative serial interface facility (RS-232/485).
♦ 24 V Loop Power Supply For Flow Transmitter
♦ Optional GSM mobile connectivity for wireless Remote access (SMS).
♦ Flow Monitoring & Data Logging Computer SoŌware Available.
♦ Available In Weather Proof Or Flame Proof Housing.
♦ Multi Parameter Auto scroll display like Steam press., temp., Nm3 and Sm3
♦ The instrument can be configured to work on SATURATED or SUPERHEATED or BOTH.
♦ Non-volatile memory to retain totalized flow, no need of battery to change.
♦ Gives efficient Pressure and Temp. Compensations for mass flow calculation.
♦ Calculates Flow rate in NM3/Hr or SM3/Hr as selected.
♦ Liner or square root input selection with 0.1% Accuracy.
♦ Isolated 0/4-20mA retransmission output proportional to standard flow rate.
♦ Field operated user friendly menu for device configurations & calibration.
♦ 8/10 digit Flow Totaliser with password protected reset.
♦ Fully password protection for tamper free operation.
♦ Isolated High speed communicative serial interface facility (RS-232/485).
♦ 2 nos. 24 Volt loop power supply for Flow & Pressure Transmitter.
♦ Optional GSM mobile connectivity for wireless Remote access (SMS).
♦ Flow Meter computer software available.
♦ Weather proof or flame proof housing.
♦ Linear or square root option and automatic unit changable.
INPUT | Input Type | Currant : | 0 ~ 20 mA DC , 4~20 mA DC |
Voltage: | 0-5 V/1-5 V, 0.5 -2.5 V/0- 1 0V DC | ||
Pulse : | 3 Wire PNP, NPN & 2 Wire NAMUR Type | ||
24 V DC @ 30 mA Max, Isolated From I/P & O/P | |||
Linear Or Square Root | |||
Range Limits | As Per Input Range Table | ||
Accuracy | +/- 0.1 % Of Span For Linear & RTD, +/-0.25 % For T/C | ||
Input Impedance | >330 K \For Voltage ,mV, And T/C, 100 R For Current | ||
INDICATION | Indication | TOUCH LCD TYPE : | 3.5 Inch Touch Screen 5 Digit Flow Rate & 10 Digit Totalizer. |
LCD TYPE : | 5 Digit Flow Rate & 10 Digit Totaliser-16x2 Line | ||
Status Indication | LEDs For Relay Status & Communication | ||
Alarm Modes | Very Low / Low / High / Very High | ||
CONTROL MODE | On Off Control | Relay / SSR | |
Dead Band Controls | High And Low Set Point for Level Application | ||
OUTPUT | Relay Output | NO - C - NC Contacts , 5A@240 V AC Resistive | |
SSR Output | 1 / 2 Relays / SSR Output | ||
Transmitter Power | 24 V DC @ 20 mA ,12 V DC @ 20 mA | ||
Retransmission Current & Voltage Outputs | 0~20/ 4~20 mA, 0 ~ 5 V , 0 ~ 1 0 V , 1 ~ 5V DC, Fully 3 Port Isolated | ||
COMMUNICATION | Communication Protocol & Method | Modbus RTU RS- 485/RS- 232 Or Ethernet Communication | |
Programmable Parameter & Max No. | Baud Rate, Parity , Node Address , Stop Bit & 0-256 Unit | ||
Wireless Communication | GSM/GPRS Base Mobile(sms) Communication | ||
PROGRAMMBALE PARAMETERS | Set point / Hysteresis / High Scale / Low Scale | Full Range As Per Input Selection. | |
Relay Logic | F.S. High & Low Alarm, Dead Band Alarm | ||
Display Resolution | -1999 to 9999 Fully Configurable For Linear Input | ||
Programming Of Parameters | Through 4 Tactile Keys | ||
OTHER | Dimensions & Mounting | As Per Box Selection & Wall/Structure 2/2 Holes | |
(A) Supply Voltage (B) Power Consumption | (A) 110/230 AC/24 V DC, 50/60 Hz (B) 4 Watts Maximum | ||
Operating Ambient Temperature And Humidity | 0~50 °C , and humidity : Below 90%, non condensing |