DATA LOGGER & RECORDERS
♦ 4,8,16,24 & 32 Channel Universal Input (RTD, Thermocouple, 0-1 /5/10 VDC, 0/4-20mA, Input Signals).
♦ On Board 15000 Reading Per Channel Storage. With Auto Data Back Filling & Data Logging.
♦ USB Port For Direct Data Logging. Optional Blue tooth & RF Wireless (2 KM).
♦ Individual HI/LO Alarm With 2 Relay Outputs. ( Optional For Each Channel).
♦ Ethernet Port (Optional) Networkable.
♦ PC Based Data Acquisition Sofware For Data Logging Reporting And Trending.
♦ 21 CFR Part 11 (Optional) None Editable File Format.
♦ Different Housing Like Front End IP65 Protection, Flame Proof.
♦ 3.5 / 7 Inch TFT With Touch Screen Control.
♦ Direct Printout To Dot Matrix Printer Or USB Printing.
♦ On Board USB Port (Memory Stick With 4 GB Memory).
♦ Can Send Direct SMS On Alarm Condition To User.
♦ Can Be Working With Wireless Probes For Pharma & Other Application.
♦ Individual Universal Input Channel Selection.
♦ Logging Intervals Can Be Set From 1 To 65535 Sec..
♦ High-Resolution 16-Bit ADC Used For Analog Input.
♦ 8 or 16 Channel universal input (RTD, Thermocouple, 0‐1 /5/10 VDC, 0/4‐20mA, input signals)
♦ Onboard 32000 Reading per channel storage.
♦ Parallel Port.
♦ Individual HI/LO alarm with 2 relay outputs. ( optional for each channel)
♦ Networkable using Ethernet Port (Optional)
♦ PC Based Data Acquisition Software
♦ 21 CFR Part 11 (Optional)
♦ Front end IP65 Protection
♦ 3.5 inch TFT With Touch Screen Control
♦ Direct Printout to Dot Matrix Printer
♦ Onboard USB Port (Memory Stick with 4 GB Memory)
♦ Can send direct sms on alarm condition to user
♦ Can send e‐mail reports
INPUT | Input Type For Input 1 to 32 channel | T/C | K, J, R, S, E, N, T |
RTD | Pt-100, Cu 53 ( 2wire & 3 wire) | ||
Current | 0 - 20 mA DC, 4 - 20 mA DC | ||
Voltage | 0 - 5 V / 1 - 5 V / 0.5 -2.5V / 0 - 10 V DC | ||
Transmitter Power Supply | 24 V DC @ 30 mA Max, Isolated From I/P & O/P | ||
Cold Junction Comp. & Sensor Break Ind. | Software Base Automatic | ||
Range Limits | As Per Input Range Table | ||
Accuracy | +/- 0.1 % Of Span For Linear & RTD, +/-0.25 % For T/C | ||
Input Impedance | >330 K For Voltage , mV , And T/C, 100 R For Current | ||
INDICATION | Indication | 4,8,16 Ch :- 3.5 Inch TFT -Touch Screen , 24,32 Ch- 7 Inch Touch Screen. | |
Status Indication | LEDs For Relay Status & Communication | ||
Alarm Modes | Very Low/Low/High/Very High | ||
MEMORY | USB Pen Drive | Direct Pen Drive For Data Memory(4 GB or 8 GB) (File Formats :- PDF Or Excel) | |
Non-Volatile Data Flash | Data Storage: 15,000 Records Per Channels With Auto Data Back Filling | ||
OUTPUT | Relay Output | NO - C - NC Contacts , 5A@240 V AC Resistive | |
Sir Output | 1 / 2 / 3 / 4 Relays / SSR output | ||
Transmitter Power | 24 V DC @ 20 mA ,12 V DC @ 20 mA | ||
Retransmission Current & Voltage Outputs | On Line Dot Metric Printer | ||
COMMUNICATION | Communication Protocol & Method | Modbus RTU RS- 485/ Ethernet TCP-IP & Wi-Fi , Bluetooth , USB | |
Programmable Parameter | Baud Rate, Parity , Node Address , Stop Bit & 0-256 Unit IP Add | ||
Wireless Communication | RF 2 KM / GPRS Base Mobile(SMS) Communication | ||
PROGRAMMABLE PARAMETER | Set point / Hysteresis / High Scale / Low Scale | Full Range As Per Input Selection. | |
Relay Logic | F.S. High & Low Alarm, Dead Band Alarm | ||
Display Resolution | -1999 to 9999 Fully Configurable For Linear Input | ||
Parameter Programming | Touch Screen. Or Through 5 Tactile Keys | ||
OTHER | Dimension & Mounting | As Per Box Selection & Wall/Structure 2/2 Holes | |
(A) Supply Voltage (B) Power Consumption | (A) 110/230 V AC/24 V DC, 50/60 Hz (B) 4 Watts Maximum | ||
Operating Ambient Temperature And Humidity | 0~50 °C , And Humidity : Below 90%, Non Condensing |