FLP UNIVERSAL PROCESS CONTROLLER (SINGLE DISPLAY)
♦ Flame Proof Low Cost And Compact Size Controller.
♦ µp Based Power, Full & Highly Reliable Controller
♦ IIA, IIB, IIC (Optional) IP 65 As Per IS 2148/1981,Certified By C.M.R.I./CCOE.
♦ Universal Input T/C, RTD, Linear Input Selection.
♦ 1 Nos. Potential Free Relay Contact Output.
♦ 0.1% Accuracy Of FSD.
♦ Isolated 0/4-20mA Process Value Re-Transmission Output.
♦ All Configurations And Calibration From Front Panel Keypad.
♦ Highly Communicative Serial Interface Facility (RS 232/485).
♦ Transmitter Loop Power Supply With Current Limit As Standard.
♦ Power Supply :230 V/110 V AC Or 24 V/12 V DC.
♦ Fully Password Protected Operation.
♦ Flame proof low cost and compact size controller.
♦ µP Based Power, full & highly reliable controller.
♦ I, IIA,IIB, IP 65 as per IS 2148/1981,certified by C.M.R.I.
♦ Universal Input T/C, RTD, Linear input selection.
♦ Potential Free Relay contact output upto ½/3/4.
♦ 0.1% Accuracy of FSD.
♦ Isolated 0/4-20mA process value retransmission output.
♦ All Configurations and calibration from front panel keypad.
♦ Highly communicative serial interface facility (RS 232/485).
♦ Transmitter loop power supply with current limit as standard.
♦ Power supply :230V/110V AC or 24V/12V DC
♦ Optional GSM mobile connectivity.
♦ Fully Password Protected Operation.
INPUT | Input Type | T/C | K, J, R, S, E, N, T |
RTD | Pt-100, Cu 53 ( 2 wire & 3 wire) | ||
Current | 0 - 20 mA DC, 4 - 20 mA DC | ||
Voltage | 0 - 5 V / 1 - 5 V / 0.5 -2.5V / 0 - 10 V DC | ||
Special On Demand | 0-75/200 mV DC & 0-1/10/100/300 V AC/DC | ||
0-75/200 mV DC ,0-100/300V DC | |||
Resistance | 0-500 R , 0-1/5/10 K, 1M | ||
Transmitter Power Supply | 24 V DC @ 30 mA DC Max, Isolated From I/P & O/P | ||
Cold Junction Comp. & Sensor Break Ind. | Software Base Automatic | ||
Range limits | As Per Input Range Table | ||
Accuracy | +/- 0.1 % Of Span For Linear & RTD, +/-0.25 % For T/C | ||
Input Impedance | >330 K For Voltage ,mV DC , And T/C, 100 R For Current | ||
FLAME PROOF | Gas Group | I IIA IIB IIC as per IS 2148/1981 - | |
Enclose Certification | Enclosure Is Certified By C.M.R.I., CCOE | ||
Cable Entry | 3/4 Inch ET, 2 Nos. / 3 Nos. | ||
CONTROL MODE | On / Off Control | Relay / SSR | |
Dead Band Controls | High And Low Set Point For Level Application | ||
OUTPUT | Relay Output | NO - C - NC Contacts , 5 A @ 240 V AC Resistive | |
SSR Output | 1 Relay / SSR Output | ||
Transmitter Power | 24 V DC @ 20 mA, 12 V DC @ 20 mA | ||
Re-Transmission Current & Voltage Output | 0 - 20 / 4 - 20 mA DC, 0 - 5 / 0 - 10 V / 1 - 5 V DC Isolated | ||
COMMUNICATION | Communication Protocol & Method | Modbus RTU RS- 485/RS- 232 Communication | |
Programmable Parameter | Baud Rate, Parity, Node Address, Stop Bit & 0-256 Unit | ||
Wireless Communication | GSM / GPRS Base Mobile(SMS) Communication | ||
PROGRAMMABLE PARAMETER | Set point / Hysteresis / High Scale / Low Scale | Full Range As Per Input Selection. | |
Relay Logic | F.S. High & Low Alarm, Dead Band Alarm | ||
Display Resolution | -1999 to 9999 Fully Configurable For Linear Input | ||
Parameter Programming | Through 4 Tactile Keys | ||
OTHER | Dimension & Mounting | FLP Wall Mount | |
(A) Supply Voltage (B) Power Consumption | (A) 110/230 V AC / 24 V DC, 50/60 Hz (B) 4 Watts Maximum | ||
Operating Ambient Temperature and Humidity | Temp. 0 - 50 °C , And Humidity: Below 90% Non Condensing |